Agilent BioTek Cytation 7 Cell Imaging Multi-Mode Reader

BioTek Cytation 7 cell imaging multi-mode reader combines automated digital upright and inverted widefield microscopy with conventional multi-mode microplate reading. For Research Use Only. Not for use in diagnostic procedures.

£-1.0

Specification

Type Automated Microscope/Multi-Mode Microplate Reader
Shaking Linear, Orbital, Double Orbital
Linearity <1% from 0 to 3 OD
Sensitivity Fluorescein 2.5 pM (0.25 fmol/well, 384-well plate) – top Fluorescein 4 pM (0.4 fmol/well, 384-well plate) – bottom; luminescence 20 amol ATP (flash)
Detection Method Monochromator- based fluorescence intensity, luminescence and absorbance
View More Specs


Specification

Type Automated Microscope/Multi-Mode Microplate Reader
Shaking Linear, Orbital, Double Orbital
Linearity <1% from 0 to 3 OD
Sensitivity Fluorescein 2.5 pM (0.25 fmol/well, 384-well plate) – top Fluorescein 4 pM (0.4 fmol/well, 384-well plate) – bottom; luminescence 20 amol ATP (flash)
Detection Method Monochromator- based fluorescence intensity, luminescence and absorbance
Dispense Volume 5 to 1000 μL, 1 μL increments
No. of Dispensers 2 Syringe Pumps
Plate Type Monochromator: 6- to 384-well plates; Imaging: 6- to 1536-well plates
Reading Options End point, kinetic, spectral scanning and well area scanning
Bandwidth 4 nm (230 to 285 nm), 8 nm (>285 nm)
Wavelength Luminescence 300 to 700 nm; Absorbance 230 to 999 nm, 1 nm increment
Wavelength Selection Quad monochromators (top/bottom)
Light Source Xenon Flash
Resolution 0.0001 OD
Scan Speed 96-wells: 11 s; 384-wells: 22 s
Temperature Range (Metric) 4-Zone incubation to 45°C with Condensation Control (±0.5°C at 37°C)
Certifications/Compliance CE and TUV marked. RoHS compliant.
Frequency 50/60 Hz
Voltage 100/240 V

BioTek Cytation 7 cell imaging multi-mode reader combines automated digital upright and inverted widefield microscopy with conventional multi-mode microplate reading. Cytation 7 includes continually variable bandpass monochromators for versatility and performance for general multi-mode plate reader applications

The inverted microscopy module provides sample visualization and the upright microscopy module with reflected light imaging enables even more applications, including ELISpot and fast slide scanning. Cytation 7 is controlled by Gen5 software, which combines ease-of-use with powerful processing and analysis capabilities.

Product Code Brand Model Price ??product.searchResults.label.quantityAvail??
Quantity
17207979
Agilent BioTek
CYT7U-SN
CYT7U POA
Add to basket
17227979
Agilent BioTek
CYT7UM-SN
CYT7UM POA
Add to basket
17247979
Agilent BioTek
CYT7UMW-SN
CYT7UMW POA
Add to basket
17267979
Agilent BioTek
CYT7UW-SN
CYT7UW POA
Add to basket